جزییات کتاب
This popular guide provides an understanding of basic design criteria and calculations, along with current inspection and testing requirements and explains how to meet the requirements of the IEE Wiring Regulations.The book explains in clear language those parts of the regulations that most need simplifying. There are common misconceptions regarding bonding, voltages, disconnection times and sizes of earthing conductors. This book clarifies the requirements and outlines the correct procedures to follow.It is an affordable referenc. Read more... Content: Cover; 17th Edition IEE Wiring Regulations: Design and Verification of Electrical Installations; Copyright; Contents; Preface; Chapter 1. Design; Assessment of general characteristics; Protection for safety; Protection against thermal effects (IEE Regulations Chapter 42); Protection against overcurrent; Protection against overload; Protection against fault current; Protection against undervoltage (IEE Regulations Section 445); Protection against overvoltage (IEE Regulations Sections 442 and 443); Isolation and switching; Design calculations; Questions; Chapter 2. Inspection and Testing Initial verificationInspection; Approved test lamps and indicators; Calibration, zeroing/nulling and care of instruments; The tests; Continuity of protective conductors; Continuity of ring final circuit conductors; Insulation resistance; Polarity; Ring final circuits; Radial circuits; Earth electrode resistance; External loop impedance Ze; Earth fault loop impedance Zs; Additional protection; Questions; Chapter 3. Special Locations IEE Regulations Part 7; Introduction; BS 7671 Section 701: bathrooms, etc.; BS 7671 Section 702: swimming pools; BS 7671 Section 703: hot air saunas BS 7671 Section 704: construction sitesBS 7671 Section 705: agricultural and horticultural locations; BS 7671 Section 706: conductive locations with restrictive movement; BS 7671 Section 708: caravan and camping parks; BS 7671 Section 709: marinas; BS 7671 Section 710: Medical locations; BS 7671 Section 711: exhibitions, shows and stands; BS 7671 Section 712: solar photovoltaic (PV) supply systems; BS 7671 Section 717: mobile or transportable units; BS 7671 Section 721: caravans and motor caravans; BS 7671 Section 729: Operating and maintenance gangways BS 7671 Section 740: amusement devices, fairgrounds, circuses, etc.BS 7671 Section 753: floor and ceiling heating systems; Questions; Appendix 1. BS 7671 Appendices; Appendix 2. Sample Questions; Appendix 3. Suggested Solutions to Sample Questions; Index Abstract: This popular guide provides an understanding of basic design criteria and calculations, along with current inspection and testing requirements and explains how to meet the requirements of the IEE Wiring Regulations.The book explains in clear language those parts of the regulations that most need simplifying. There are common misconceptions regarding bonding, voltages, disconnection times and sizes of earthing conductors. This book clarifies the requirements and outlines the correct procedures to follow.It is an affordable referenc